| System | Solar | Battery | Inverter | Water | Typical Deploy |
|---|---|---|---|---|---|
| Box 20 HybridSolar + onboard battery | 78.54 kWp | 122.88 kWh | 2 × 50 kW hybrid | None | Under 3 hours |
| Box 20 PowerSolar only. Pairs with generators or storage | 107.1 kWp | None | 100 kW (110 kVA max) | None | Under 3 hours |
| Box 10 HybridSolar + onboard battery | 23.8 kWp | 61.44 kWh | 1 × 50 kW hybrid | None | Under an hour, two operators |
| Box 10 PowerSolar only. Pairs with generators or storage | 47.6 kWp | None | 50 kW | None | Under an hour, two operators |
| TowTowable trailer, about 3,300 lb | 12 kWp | 20.48 kWh | 15 kW | None | 30 minutes |
| WaterContainer with onboard water generation | 54.7 kWp | 61.44 kWh | On request | Up to 264 gal per day, depending on humidity | Under 3 hours |
Solar, battery, inverter, and water figures are from the current Nomad Solar Energy datasheets. Deploy times are typical, not datasheet values: they run from arrival to power and depend on the site.
Open a System
For the Full Spec
20-foot ISO Container · Power or Hybrid
Nomad Energy Box 20
107.1kWpMax Solar / Power
10-foot · Expeditionary · Power or Hybrid
Nomad Energy Box 10
61kWhBattery / Hybrid
Towable Trailer · Typical 30-Minute Deploy
Nomad Energy Tow
30minTypical Setup
Solar + Atmospheric Water
Nomad Energy Water
264galUp To / Day, By Humidity
Four Questions
Pick the Platform
Power After Dark?
If the site needs power at night without an engine running, choose a Hybrid Box or the Tow. Each carries its own battery and stores daytime solar for the night.
Hybrid vs PowerGenerators on Site?
If you already run generators or storage, a Power version carries the most solar per container and takes part of the daytime load off them, so they burn less fuel. A generator or storage unit stays on beside it.
Size the SystemCrew on the Move?
If the work relocates often, the Tow hitches to a suitable tow vehicle and typically deploys in 30 minutes. The Box 10 is the smallest container in the lineup, moved by truck and placed by crane or forklift.
See the TowWater Resupply?
If water deliveries are part of the problem, the Water draws it from the air: up to 264 gal per day, depending on humidity. Its own solar and battery run it off-grid, and it can tie into diesel or grid power where either is on site. Off-grid, daily output also depends on the sun and the battery, so your brief estimates it for your site.
How It WorksBefore You
Request a Brief
Solar vs Diesel Generators
Fuel, noise, and maintenance compared, where diesel still fits, and when to choose a Hybrid or a Power system. 02How to Size a Mobile Solar Generator
kW vs kWh, peak sun hours, battery for the night, and a worked example run through the calculator. 03How Atmospheric Water Generators Work
How water comes out of the air, why humidity and temperature drive output, and how solar runs it off-grid. 04Cutting Fuel Convoys at Forward Bases
Where base fuel goes, why generators waste it, and how solar and battery power shorten the fuel line.Straight
Answers.
What is the difference between Power and Hybrid?
Power is solar only, with no battery, and pairs with the generators or storage you already run. Hybrid adds an onboard battery for power after dark. The Box 20 and Box 10 come in both versions. The Tow and the Water each come in one version with the battery onboard.
Which systems run at night on their own?
Every system with an onboard battery: the Box 20 Hybrid, the Box 10 Hybrid, the Tow, and the Water. How long each runs after dark depends on your load, which we size in your brief. The Power versions have no battery and work alongside your generators or storage.
Can we deploy more than one unit on a site?
Yes. Multiple units can be deployed across a site. Your brief sets the number and mix of units for your load, your sun, and how the site runs at night.
How do I estimate what a system will save?
Start with the savings calculator. Enter the diesel your generators burn today and the sun at your site, and it estimates the gallons a system could offset each year, with every assumption shown. An engineer checks the numbers against your site in your brief.
Not Sure Which Fits?
We'll Size It.
Tell us the site, the load, and the generators you run today. An engineer matches the system and returns pricing to buy, lease, or rent, typically within one business day.
- 01Engineering review of your load and site.
- 02System match with pricing to purchase, lease, or rent.
- 03A clear path to deploy.
Copy your brief and send it to rturpin@nomadamerica.energy from any email account.